-77-
S
S
C
C
Step
60
(min: 4x20sec; max:
4x180sec)
In case of „20“ check:
70
(4x 30 sec)
In case of „60“ check:
75
(min 80sec
max 1000 sec)
In case of „12“ check:
90
(min 360sec
max 1000 sec)
100
(min: 4x20sec; max:
4x60sec
In case of „20“ check:
110
(4x 30Sec)
Step 90,100 and 110
will run 1x for each
rpm setting!
In case of „70“ check:
900
Unit status:
Controlling with all 4 fan speeds:
Steam Heating: ON 50%
• Motor: ON
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Measuring at all 4 fan speeds:
Calibration value: Steam
• Heating: ON 50%
• Motor: ON
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Step 60 and 70 will run 1x for each rpm setting!
Heating of cabinet in combi. to 193°C (380°F)
Hot air heating: ON
• Steam Heating: ON
(when Hot air off)
Motor: ON ( max rpm)
Humidity fl ap: Closed
Hot air elements, SSR, cabinet sensor
Combination 170°C (338°F)
Hot air heating: ON 50%
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm)
Humidity fl ap: Closed
Controlling with all 4 fan speeds:
Steady signal of rpm and pressure
Hot air heating: ON 50%
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm fi rst)
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Measuring at all 4 fan speeds:
Calibration value: Combination
Hot air heating: ON if needed
Steam Heating: ON (when Hot air off)
Motor: ON (max rpm fi rst)
Humidity fl ap: Closed
In diagnostic mode: P1, B4, rpm
Step 90,100 and 110 will run 1x for each rpm setting!
End – Exit diagnostic program and set DIP 1 to OFF
For immediate data storage switch unit off and on
again!
Error code
20
71
60
12
71
none
20
71
70
Reason:
Value out of
allowable range;
Max time of
4x180sec exceeded
Calibration value
not in expected
range (logic)
No hot air heating
Max time of
1000sec exceeded
Value out of allo-
wable range
Max time of
4x240sec exceeded
Calibration value
not in expected
range (logic)
Status: 01.09.2005
Calibration SCC