Rational CombiMaster CM Bedienungsanleitung Seite 111

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 186
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 110
-111-
S
Fault List SCC
Service 10
Unit shows Service 10
Activate function test
Level electrode of the steam
generator did not recognise a
reduction of the water level during
last SC-Automatic
Info
Select step 8
SC Pump M4
and touch "Start" key
Pump active, water is
pumped off
Short circuit level electrode or
check drain system and
quenching box for dirt,
clean if necessary
yes
230V output at I/O-pcb X18
1/2 during function test?
Fuses F6/F6.1
(on I/O pcb)
ok?
Change fuse
Check cable and
pump for short circuit
Change I/O-pcb
Check pump for scale
deposits or other dirt,
that blocks the impeller
Clean housing of the pump,
descale steam generator
and /or change pump
no
no
no
Check cable, connector
and pump.
Change defective part
yes
yes
Auxiliary contact 13/14
of contactor K1
ok?
no
Change auxiliary
contact or contactor
no
yes
Seitenansicht 110