-112-
S
Fault List SCC
Service 11
Indication Service 11
shown every time unit is
switched on
Water supply from
CDS to steam
generator leaking
Eliminate leak
Actual measured filling volume
above reference volume of steam
generator
Info
Check valve in the water
supply line to the steam
generator.
Valve working correctly?
no
yes
Change valve
Start volume measuring
by activating pumping
function,
first touch function- then
service- and finally key
for emptying steam
enerato
Level electrode clean,
cable and connector ok?
no
yes
Clean electrode,
change defective part
no
yes