M
Since software version C1-07-01 the last 10 error messages are shown.
Er When Timer key is pressed the error code will be displayed, i.e.
Er1 3 B1 Cabinet sensor defective
Er2 14 Y1 Filling solenoid defective
Er3
--
--
Er10
Since software version C1-07-01 the last 16 gas error messages are shown
in addition to the general error messages (gas units only!)
GE11 20 No rpm signal
GE12 32 No fl ame after 5 ignition sequences
GE13
--
--
GE25
GE26
Indication of ignition box error messages (1-32 is shown to the operator as „rES“):
1 Hot air or Steam no gas, gas valve or electrode defective
14 Hot air gas valve controll, change ignition box
19 Hot air no fl ame because fl ame current is too low
check burner setting, fl ame current, ignition cable and plug
20 Hot air wrong or no rpm signal from gas blower
check gas blower, power supply gas blower and control harness of gas blower
22 Hot air no fl ame after 5 ignition sequences
no gas, gas valve or electrode defective
24 Steam gas valve controll, change ignition box
29 Steam no fl ame because fl ame current is too low
check burner setting, fl ame current, ignition cable and plug
30 Steam wrong or no rpm signal from gas blower
check gas blower, power supply gas blower and control harness of gas blower
32 Steam no fl ame after 5 ignition sequences
no gas, gas valve or electrode defective
Possible failure in case of „E21“
33, 36 Change ignition box
35 Check frequency of main
39 Hot air Check burner setting, ignition electrode and distance,and fl ame current
40 Hot air Check ignition cable
42 Steam Check burner setting, ignition electrode and distance,and fl ame current
43 Steam Check ignition cable
Is shown on display „CHnG PoL“
34 Change polarity of mains
All other numbers (2-13, 15-18, 21, 23, 25-28, 31): change ignition box